Skip to content

Latest commit

 

History

History
41 lines (29 loc) · 2.05 KB

m5stack-atoms3.md

File metadata and controls

41 lines (29 loc) · 2.05 KB

Connecting Zehnder Comfoair Q with M5Stack Atoms3 Lite + Mini CAN Unit

Before you start, make sure you have already flashed the firmware on the ESP32 board. If you haven't done that yet, please follow the instructions in the README.

Components

How

  1. Connect the Dupont jumper cables to the Zehnder ventilation unit (see diagram below). Zehnder CAN connection with jumper cables
  2. Connect the other side of the Dupont jumper cables with Mini CAN unit (see diagram below). Make sure you connect the cables correctly. Mini CAN unit connection with jumper cables
  3. Connect the Mini CAN unit with the M5Stack Atoms3 Lite board using the 4-pin grove cable.

Here is a picture of the finished setup: AtomS3 Lite + Mini CAN connected to Zehnder ComfoAir Q

Connection diagram


|-----------------+                                    +-------------+
|                 |     +----------------------+       |             |
|   [ComfoAir]    |     |       [MiniCan]      |       |  [ESP32S3]  |
|                 |     |     [TJA1051T/3]     | Grove |             |
| (red)       12V o-----o HV               RXD o=======o GPIO1       |
| (black)     GND o-----o GND              TXD o=======o GPIO2       |
| (yellow)  CAN_L o-----o CAN_L             5V o=======o 5V          |
| (white)   CAN_H o-----o CAN_H            GND o=======o GND         |
|                 |     |                      |       |             |
|-----------------+     +----------------------+       +-------------+